ODVA is pleased to announce that the CIP SafetyTM on EtherNet/IPTM technology has been enhanced to allow for the use of Concurrent Connections for applications requiring both high availability and functional safety. Concurrent Connections allow for communication redundancy between multiple producing and consuming devices for the most critical automation processes. CIP Safety provides fail-safe communication between nodes such as safety I/O blocks, safety interlock switches, safety light curtains and safety controllers in both machine and process automation safety applications up to Safety Integrity Level (SIL) 3 according to IEC 61508 standards. The use of Concurrent Connections with CIP Safety on EtherNet/IP allows for redundancy and functional safety to be integrated to ensure the best uptime and worker safety.
Concurrent Connections are CIP connections that support fault tolerance via redundant devices. Concurrent Connections enable many CIP connection paths, which allows data to be sent multiple times over multiple paths between the producing and consuming devices, independent of how the devices are physically interconnected. Originators, routers, and targets can all have multiple devices participating, and the Concurrent Connection and any of the duplicated device pairs can fulfill the role and the connection. This reduces time that would otherwise be needed to detect failures and eliminates the time that would have to be spent switching between paired devices. The redundant pair send and receive data continuously, so even if a failure is detected in one of the devices, the control process can continue uninterrupted.
CIP Safety mitigates common errors that can result in hazardous situations via various techniques as described in IEC 61784-3-2. Time stamps are used with time expectation to detect if packets are lost, delayed, repeated or transmitted out of order. Unique device identifiers are used to authenticate the communication between two safety devices. Additional diagnostics and checks are included to validate that the messages are not corrupted in transit and all these features are separate from standard communication methods. When these mitigations are put together as CIP Safety, a single connection between two devices (wired or wireless) can be used for communications certified up to SIL 3 per IEC 61508 and up to Category 4/PLe per ISO 13849-1.
“The availability of Concurrent Connections for CIP Safety on EtherNet/IP creates a whole new level of assurance that industrial networks will be both resilient and safe in the face of device failure or communication errors,” according to Dr. Al Beydoun, President and Executive Director of ODVA. “Concurrent Connections for CIP Safety is a win-win that offers the highest availability and functional safety together to enable the toughest applications to be handled while reducing injuries and increasing output.”
CIP Safety and Concurrent Connections have been available separately to provide industrial network functional safety and redundancy in the case of device errors or failure. The purpose of Concurrent Connections for CIP Safety is to provide automation network designers with a way to leverage both the higher system availability advantages offered by standard Concurrent Connections while maintaining the safety integrity offered by CIP Safety connections. Visit odva.org to obtain the latest version of The EtherNet/IP Specification and The CIP Safety Specification for all the details on Concurrent Connections for CIP Safety on EtherNet/IP.
About ODVA
ODVA is an international standards development and trade organization with members from the world’s leading automation suppliers. ODVA’s mission is to advance open, interoperable information and communication technologies for industrial automation. Its standards include the Common Industrial Protocol or “CIP
For more information, contact:
Steven Fales
ODVA
4220 Varsity Drive, Suite A, Ann Arbor, MI 48108-5006 USA
TEL +1 734 975 8840
Fax +1 734 922 0027
Email sfales@odva.org
DeviceNet is a registered trademark of ODVA, Inc. CIP, CIP Safety, and EtherNet/IP are trademarks of ODVA, Inc. Other trademarks are property of their respective owners.
About ODVA
ODVA is an international standards development and trade organization with members from the world’s leading automation suppliers. ODVA’s mission is to advance open, interoperable information and communication technologies for industrial automation. Its standards include the Common Industrial Protocol or “CIP
ODVA, Inc.
4220 Varsity Drive
Ann Arbor, MI 48108
Michigan
USA
Fales Steve
Phone : +1 734-975-8840, ext. 1365
Fax : +1 734-922-0027 +1 734-922-0027
sfales@odva.org